Chlorine analyser

€3,500.00

DESCRIPTION:

The Series RAH-210 Analyzer makes use of the Amperometric method to determine residual levels

in the sample water. The measurement cell consists of large Gold and Copper electrodes in direct

contact with the sample water. The measurement is continuous, not relying on sample and hold

methods, thereby allowing for better process control. A continuously driven cleaning system is

employed to prevent the build up of impurities on the surface of the electrodes and reduce the need

for maintenance.

The Series RAH-210 Free Chlorine Analyzer is available with pH & Temperature compensation

performed in software. For applications with consistent pH levels in the process water, the known

pH value can be manually input for software compensated residual analysis. A gravity driven buffer

feed system is also available to inject the required chemicals for measuring Total Chlorine, Chlorine

Dioxide, Iodine and Bromine. For Free Chlorine measurement, vinegar can be used as the pH buffer

reagent. The measurement range is field adjustable through menu driven digital programming.

This analyzer includes a complete PID control program as a standard feature.

INSTRUMENTS

1501 W. Park Avenue, Perkasie, PA 18944

 

Temperature Range: 0 to 50 C (32 to 120 F)

Sample Water Flow Rate: 500 ml/minute (0.13 GPM or 8 gal/hr)

Sample Pressure: 5 psig (0.3 bar) maximum at inlet point.

Sample Supply: Continuous. Electrodes must be kept wet with fresh water.

Speed of Response: 4 seconds. Full-scale residual change 90 to 120 seconds.

Sample Water: Metal ions or corrosion inhibitors effect operation.

Range: 0 to 0.1 to 0 to 20 mg/l (PPM). Field adjustable.

Accuracy: 0.003 mg/l or +/-1% of range, whichever is larger.

Sensitivity: 0.001 mg/l (1 ppb)

ELECTRICAL

Power Consumption: 10 W max

Power Requirements: 120VAC, 50/60 Hz or 240VAC, 50/60 Hz, single phase

Output Signal: (2) 4-20 mA

Relay Contact: 10 Amps @ 120 VAC or 24 VDC, resistive load, 5 Amps

@ 240 VAC, resistive load

REAGENT REQUIREMENTS

Measured Chemical Residual Reagents Required

Free Chlorine (pH Compensated): None

Free Chlorine (not pH Compensated): pH Buffer or CO

Total Chlorine: pH Buffer or CO

Chlorine Dioxide: pH Buffer and Glycine

Bromine Chloride: pH Buffer or CO

Iodine: pH Buffer or CO

2 gas2 gas and Potassium Iodide2 gas and Potassium Iodide2 gas

Series RAH-210

Residual Chlorine Analyzer

INSTRUMENTS

Basic Specifications:

 

Series RAH-210

Residual Chlorine Analyzer

• Amperometric Residual Analyzer

• Available with pH & temperature

compensation without buffer chemicals

for Free Chlorine

• Free Chlorine, Total Chlorine, Chlorine

Dioxide, Bromine, and Iodine

• Includes complete PID control program

(standard)

• Provides two analog outputs (selectable

between residual, pH and control signals)

and one alarm relay

• Adjustable measurement range

• Continuous Measurement/Fast Response

• Continuous sensor cleaning mechanism


Add to Cart:

  • Model: RAH-210
  • 1 Units in Stock
  • Manufactured by: EasyTele


This product was added to our catalog on Wednesday 15 July, 2009.